Turn a wall line into a lumber order: stud count from run length and on-centre spacing, the plate stock along floor and top, and total board feet.
The calculator's own fields, action and results arrive with the verified pack when you load it. Nothing is computed in this page.
On-centre spacing is measured from the middle of one stud to the middle of the next, and it is the wall’s module. Sheathing and drywall are sized so their edges meet over a stud centre; insulation batts are milled to drop into the cavity the module leaves. The classic residential spacing of sixteen inches on centre is a compromise between stiffness and lumber; wider modules appear on non-bearing partitions and in engineered framing, and the spacing input is how the take-off is told which rhythm the wall keeps.
The count itself is the fence-post problem wearing a tool belt. Dividing the run by the spacing counts the intervals; the studs stand at the boundaries of those intervals, so one more is needed to close the far end. The engine rounds the division up before adding the closer, because a partial interval at the end of the run still needs a stud to carry the last sheet edge — rounding down would leave the wall short exactly where the finish work notices.
Plates are the horizontal members the rhythm is nailed into: a bottom plate on the floor, a top plate above, and a cap plate doubling the top in conventional bearing walls — the doubling laps at corners to tie walls together and spreads any joist that lands between studs. The plate figure reports that stock as run lengths of the same wall line, which is how a framer calls it out at the yard.
Board feet is the lumber trade’s own volume unit, and it is what lets a mixed order be priced as one quantity. A nominal two-by-four is named for the rough-sawn size it no longer has; the engine carries the true dressed section of that stud inside the arithmetic, so the board-foot total reflects the wood that actually arrives, studs and plate stock together, rather than the name on the price tag.
What the count deliberately excludes is everything that interrupts the rhythm. Openings demand king studs, jack studs, headers and cripples; corners and intersecting partitions consume extra studs; blocking and fire-stopping have their own logic. This take-off prices the straight run those details are added to, and whether the wall is adequate for its loads is a question for the framing plan and the professionals responsible — never for a count.
The pack’s anchor vector: a wall forty feet long, framed at the classic sixteen-inch on-centre module, with studs nine feet tall — a long garage or shop wall, framed conventionally.
Three figures come back. The stud count carries the rounded-up intervals plus the closer at the far end; the plate length reports the same wall line taken as bottom, top and cap runs; and the board-foot total converts the whole frame into the unit the yard prices. Read the count against the spacing first — every stud the module demands is a stud the sheet goods are counting on.
Every figure in this example is produced by the certified engine when the calculator loads, checked against the signed pack’s declared test vectors; nothing on this page stores an answer. Widen the spacing input and watch the count fall while the plates hold still — the plates belong to the line, the studs to the rhythm.
The straight run to be framed, in feet, measured along the plate line. Each wall of a room is its own run — corners belong to the corner assemblies, not to the count — and summing walls before counting misplaces the closing stud every run needs.
The distance from stud centre to stud centre, in inches. The default expresses the classic residential module; wider spacings suit some non-bearing and engineered walls. The framing plan and the adopted local code decide what the project may use — this input only tells the take-off what was decided.
The stud length, in feet — floor to top of the wall, which is what the board-foot figure prices. Taller storeys buy their lumber twice: once in longer studs, once in the stiffer framing a tall wall often demands, and only the first of those is arithmetic.
Standard framing take-off arithmetic (stud-and-plate convention)
Stud count as the run divided by the on-centre spacing, rounded up, plus the closing stud; plate stock as run lengths of the wall line; board feet from the dressed section of the nominal stud carried over studs and plate runs.
Quantity reference to be verified against the framing plan and the professionals responsible for the structure; structural adequacy is never determined here. The signed pack carries its own citation, and the page reports the verification state of the release it mounted.